2
3
2
2
Availability: | |
---|---|
Quantity: | |
Metal Lights/Hydraulic Mast
4X 1000 W metal halide lights with Kubota engine and 8kW generat. Option for up to 20kW generator with plenty of extra power to run tools. The rotating, articulated hydraulic mast can reach out to the front, back and side for additional flexibility. The light bar also tilts 1800-and each light can point in a specific direction as well using a simple spring clip Standard engine protection includes high water temperature and low oil auto shutdowns. Quick disconnect lights and ballasts allow for easy troubleshooting, service, and repair. Standard Dot approved run stop and turn lights. Heavy duty chassis and 4,200 lbs rated axle to handle rough road towing. Highway safety chains with snap hook.
Light coverage m2:4.000 (average 20 luxes)
Lamps | Halogen lamps |
mast | Vertical hydraulic |
feartures | Wing canopy |
performance Data | ||
Rated Frequency | HZ | 50/60 |
Rated Voltage | VAC | 230/120 |
Rated Power(PRP) | KW | 6/8 |
Operating Temperature(min/max) | ℃ | -25~50 |
Sound Pressure Level@1m | dB(A) | 90 |
Sound Power @7m | dB(A) | 65 |
Power output | ||
Auxiliary Power | KW | 2/4 |
Lights | ||
Floodlights | Halogen lamps | |
Wattage | W | 4 x 1000 |
Mast | ||
Type | Hydraulic | |
Rotation | Degrees | 360 |
Maximum Height | m | 9 |
Maximum Speed wind | km/h | 80 |
Enclosure and Trailer | ||
Type | Ball or hitch fix or adjustable towbar or site trailer with leaf or rubber suspension | |
Base Frame | ||
Enclosure | Steel canopy and powder coating paint | |
Dimensions and weight | ||
Dimensions in transport fix towbar(L*W*H) | m | 2,35 x 1,6 x 2,5 |
Weight | kg | 1150 |
Engine: Kubota, Perkins, Yanmar, Yangdong
Alternator: Stamford, Leroy-Somer, DIY high quality copy Stamford
Lights: Halogen lamps, LED
Mast: Manual, Hydraulic
Folder: laydown, vertical
Maximum Height: 6m, 8m, 9m, 10m
Spare Parts: 500 hours, 1000 hours,3000 hours
Engine | ||
Model | Kubota D1105-E2BG | |
Speed | RPM | 1500/1800 |
Rated Net Output(PRP) | KW | 8.4/9.5 |
Coolant | Water | |
Number of cylinders | 3 | |
Alternator | ||
Model | DIY164G65 | |
Rated output | KVA | 6/8 |
Insulation/Enclosure protection | Class/IP | H/23 |
Consumption | ||
Fuel tank capacity | Litre | 100 |
Runtime before with lamps ON | hrs | 60 |