Cummins
DIY-C44A
44kVA/35kW
40kVA/32kW
N/A
50-1500RPM
Cummins 4BT3.9-G1
China State II
Leroy-Somer TAL-A42-F
| Availability: | |
|---|---|
| Quantity: | |
| Frequency | 50Hz | 60Hz |
| Voltage-Phases*1 | 400V/ 3Phases | N/A |
| Power Factor | 0.8 | N/A |
| Standby Power(ESP)*2 | 44kVA/35kW | N/A |
| Prime Power(PRP)*3 | 40kVA/32kW | N/A |
| Continuous Power(COP)*4 | N/A | N/A |
| Max Current | 64Amps | N/A |
| Structure Type | Open Frame | Soundproof Canopy |
| Dimension L*W*H (mm) | 1750*980*1500mm | 2240*1090*1685mm |
| Weight (kgs) | 780kgs | 1150kgs |
| Sound Pressure Level: dB(A) | 85dB(A)/7meter @ 75%Load | 75dB(A)/7meter @ 75%Load |
| Fuel Tank Capacity (Litres) | 130L | 70L |
| Automatic Run Time | 11 Hours @ 75% Load, 8 Hours @ 100% Load | |
| Engine Brand(Manufacturer) | DCEC Cummins | |
| Engine Model | 4BT3.9-G1 | |
| Aspiration Type | Turbocharged | |
| Engine Type | 4-Stroke Diesel | |
| Number of cylinders | 4 cylinders in Line | |
| Bore and Stroke | 102*120 mm | |
| Displacement | 3.9 L | |
| Compression Ratio | 17.3:1 | |
| Fuel Injection System | BYC A Direct Injection | |
| Engine Emission: | China State II | |
| Starting System | Cranking Motor-12/24V | |
| Speed Governor System | Electronic Governor | |
| Speed | 1500RPM | |
| Gross Engine Standby Power | 35kW | |
| Gross Engine Prime Power | 32kW | |
| Gross Engine Continuous Power | N/A | |
| Fuel Consumption@Standby Power | 228g/kW.h | |
| Fuel Consumption@Prime Power | 229g/kW.h | |
| Fuel Consumption@75% Power | 241g/kW.h | |
| Alternator Brand(Manufacturer) | Leroy-Somer | |
| Alternator Model | TAL-A42-F | |
| Power Ratings (PF=0.8) | 50Hz at 400V*5 | 60Hz at 220V*6 |
| Continuous Power (H:125/40°C) | 45kVA/36kW | N/A |
| Standby Power (H:163/27°C) | 50kVA/40kW | N/A |
| Poles Numbers | 4 | |
| Winding Leads | 6/12 | |
| Connection Type | Y (Star) | |
| Winding Pitch | 2/3 | |
| Insulation Class | H | |
| IP Class(Protection) | IP23 | |
| Waveform: NEMA = TIF | < 50 | |
| Waveform : I.E.C. : THF | < 2 % | |
| AVR Type | R120 (Standard) | R180 (Optional) |
| AVR Voltage Regulation | ± 1 % | ± 0.5 % |
| Excitation System | Self-Excited | AREP/PMG (Optional) |
| Short-circuit Current | 3 In: 10 seconds | |
| Control System | Auto-Start 1001 | AMF 2001 |
| Generator Voltages | ● | ● |
| Generator Currents | ● | ● |
| Generator Frequency | ● | ● |
| Generator Apparent power (Kva) | ● | ● |
| Generator Active power (Kw) | ● | ● |
| Generator Reactive power (kVAr) | ● | ● |
| Generator Power factor | ● | ● |
| Engine Speed RPM | ● | ● |
| Engine Coolant temperature | ● | ● |
| Engine Oil pressure | ● | ● |
| Fuel level (%) | ● | ● |
| Battery voltage | ● | ● |
| Battery charge alternator voltage | ● | ● |
| High/Low Voltage Protection | ● | ● |
| High/Low Frequency Protection | ● | ● |
| Over Load Protection | ● | ● |
| Short-circuit Proteciion | ● | ● |
| Over Speed Protection | ● | ● |
| High Coolant Temp. Protection | ● | ● |
| Low Oil Pressure Protection | ● | ● |
| High/Low Battery Voltage Protection | ● | ● |
| Total Running Hours Counter | ● | ● |
| Total Starting Times Counter | ● | ● |
| Total Power kWh | ● | ● |
| Total Power kWArh | ● | ● |
| Cummunications by RS232/485 | ● | ● |
| Remote Monitor by PC Software | ● | ● |
| Remote Start | ● | ● |
| Auto Mains Failure Start | ● | |
| Mains Voltages | ● | |
| Mains Frequency | ● |