When selecting a diesel generator set, the alternator is just as important as the engine. It converts mechanical energy into electrical power and directly affects voltage regulation, motor starting performance, efficiency, and the generator's ability to support different electrical loads.
Two established names in the generator alternator market are STAMFORD and Leroy-Somer. Both offer alternators for commercial, industrial, standby, and continuous power applications, but their product ranges, excitation systems, and available configurations differ.
So, which is better: a Stamford or Leroy Somer alternator?
The answer depends on your generator capacity, electrical load, starting requirements, excitation system, installation conditions, and local technical support.
In this guide, DIYPOWER compares Stamford and Leroy Somer alternators to help you make an informed selection for your diesel generator project.
Table of Contents
Both manufacturers offer reliable alternator technologies for diesel generator applications. However, comparing specific models is more useful than choosing based solely on brand reputation.
Comparison Factor |
Stamford Alternator |
Leroy Somer Alternator |
|---|---|---|
Manufacturer |
Cummins Generator Technologies |
Nidec Power |
Main product families |
STAMFORD S Series and other ranges |
LSA, TAL and specialized ranges |
Excitation systems |
Model-dependent; self-excited, auxiliary winding and PMG configurations |
Model-dependent; SHUNT, AREP, PMG and other configurations |
Voltage regulation |
Depends on AVR and excitation system |
Depends on AVR and excitation system |
Motor starting |
Depends on specific model and excitation configuration |
Depends on specific model and excitation configuration |
Nonlinear load performance |
Requires evaluation of winding, excitation and load data |
Requires evaluation of winding, excitation and load data |
Application range |
Standby, prime, industrial and specialized power |
Standby, prime, industrial and specialized power |
Replacement parts |
Model-specific genuine parts |
Model-specific genuine parts |
Engine compatibility |
Subject to mechanical and electrical matching |
Subject to mechanical and electrical matching |
Selection priority |
Rated output, transient performance and local support |
Rated output, transient performance and local support |
Quick answer: Neither brand is universally better. A properly sized Stamford alternator may perform better than an unsuitable Leroy-Somer model, and vice versa. The correct comparison must be based on models operating under the same electrical and environmental conditions.
STAMFORD alternators are manufactured by Cummins Generator Technologies under the STAMFORD | AvK brand portfolio.
They are widely used in generator sets supplying standby, prime and continuous power in commercial, industrial and infrastructure applications.
The product portfolio includes alternators across a broad range of capacities, with different frame sizes, excitation systems, automatic voltage regulators (AVRs) and optional features.
Depending on the model, important characteristics may include:
Brushless synchronous alternator construction
Automatic voltage regulation
Optional or integrated excitation arrangements
Multiple voltage and frequency configurations
Different insulation and enclosure options
Support for a range of diesel and gas engine applications
For current model information and technical specifications, see the official STAMFORD Alternator Product Range.
The excitation system supplies the electrical energy needed to establish and regulate the alternator's magnetic field.
STAMFORD alternators can use different excitation arrangements, depending on the model.
Self-excited systems derive excitation power from the main alternator output. These can be appropriate for many conventional loads, but their performance during severe voltage dips must be evaluated carefully.
PMG-excited systems use a separate permanent magnet generator to supply the AVR, helping reduce the dependence of excitation power on main terminal voltage.
Other configurations, such as auxiliary-winding arrangements, may also be available on selected models.
The most suitable excitation system depends on load characteristics, motor starting requirements and protection coordination.
Leroy-Somer alternators are part of the Nidec Power portfolio and are used in a wide range of industrial power generation applications.
The product range includes TAL and LSA alternators, along with other configurations designed for specialized applications.
Different models are available for diesel and gas generator sets, industrial power systems and other generation equipment.
Key considerations may include:
Brushless synchronous alternator designs
Different AVR and excitation configurations
Industrial and standby operating ratings
Multiple voltage and frequency options
Application-specific winding and enclosure configurations
Model-dependent thermal and transient performance
According to the official Nidec Power product overview, the TAL range serves standard applications, while the LSA range covers standard and critical applications across multiple power ratings.
For more details, refer to the Leroy-Somer / Nidec Power Product Overview.
One recognized Leroy-Somer excitation technology is AREP, which uses auxiliary windings to provide excitation power to the automatic voltage regulator.
This arrangement can help maintain excitation performance when the main output voltage changes under demanding load conditions.
AREP configurations may be useful in applications involving:
Motor starting
Sudden load changes
Certain nonlinear loads
Generator applications requiring appropriate short-circuit performance
However, AREP is not the only excitation system offered within the Leroy-Somer product portfolio.
The actual capability depends on the alternator model, winding configuration, AVR and published performance data.
Excitation technology is one of the most important technical considerations when comparing specific Stamford and Leroy-Somer alternators.
Two commonly discussed configurations are Stamford alternators equipped with PMG excitation and Leroy-Somer alternators equipped with AREP excitation.
A Permanent Magnet Generator (PMG) supplies power to the AVR independently of the main alternator output terminals.
During a sudden load increase, the main alternator voltage may temporarily decrease.
Because the PMG provides a separate excitation source, it can help maintain the AVR's ability to control excitation under these conditions.
Potential benefits include:
Reduced dependence on main output voltage for AVR supply
Support for demanding transient loads
Excitation performance suitable for selected nonlinear loads
Short-circuit current support where specified by the manufacturer
The actual performance depends on the specific PMG, AVR, alternator and operating conditions.
AREP excitation uses auxiliary windings within the alternator to supply the voltage regulator.
These windings provide excitation power based on electrical conditions in the alternator.
This arrangement can improve excitation support during load disturbances compared with certain basic self-excited configurations.
Potential benefits include:
Excitation support during voltage disturbances
Suitability for selected demanding electrical loads
No separate PMG assembly in conventional AREP configurations
Model-dependent motor starting and fault current performance
Feature |
PMG Excitation |
AREP Excitation |
|---|---|---|
Excitation power source |
Separate permanent magnet generator |
Auxiliary stator windings |
Dependence on main output voltage |
Reduced |
Reduced through auxiliary winding arrangement |
Motor starting |
Model-dependent |
Model-dependent |
Short-circuit support |
According to specific model ratings |
According to specific model ratings |
Mechanical arrangement |
Includes PMG assembly |
Uses auxiliary winding arrangement |
Main selection factor |
Required performance and model specifications |
Required performance and model specifications |
Which is better?
PMG and AREP can both provide suitable excitation performance for demanding generator applications.
It would be inaccurate to conclude that AREP always provides better motor starting or that PMG always delivers better voltage regulation.
For a meaningful comparison, request the manufacturer's published transient voltage dip, voltage recovery and motor starting data for the specific models being considered.
Motor starting is particularly important for diesel generator sets operating pumps, compressors, industrial machinery and HVAC systems.
When an electric motor starts, it may draw substantially more current than during normal operation.
The resulting current demand can cause a temporary voltage dip at the generator terminals.
If the dip is excessive, other connected equipment may malfunction or disconnect.
Motor starting performance depends on:
Alternator rated capacity and frame size
Excitation system and AVR
Motor starting method
Motor starting kVA
Existing electrical load
Generator engine transient response
Acceptable voltage and frequency deviations
Both Stamford and Leroy-Somer offer alternator configurations suitable for motor starting applications.
However, the brand name alone does not determine starting performance.
Consider a diesel generator supplying a manufacturing facility with multiple running loads and a large water pump.
When the pump starts, its temporary current demand may cause a voltage dip.
Before selecting the alternator, the engineer should determine:
Pump motor rating
Starting current or locked-rotor kVA
Starting method
Existing generator running load
Maximum acceptable voltage dip
Required voltage recovery performance
Using these values, the generator supplier can compare suitable Stamford and Leroy-Somer model data.
For broader generator capacity planning, see our Generator Set Selection Guide.
Modern generator sets frequently supply equipment containing power electronics.
Typical nonlinear loads include:
Variable Frequency Drives (VFDs)
Uninterruptible Power Supplies (UPS)
Industrial rectifiers
Switching power supplies
Certain electronic lighting systems
These loads can introduce harmonic currents and affect voltage waveform quality.
Alternator winding design can influence the voltage waveform and harmonic behavior.
For example, a 2/3-pitch winding is commonly used in generator applications to reduce certain triplen harmonic components in generated voltage.
However, this design does not eliminate all harmonic distortion caused by nonlinear loads.
The overall harmonic performance depends on the complete electrical system.
Important factors include:
Alternator winding configuration
Load harmonic spectrum
AVR and excitation performance
Alternator reactance
Connected UPS and VFD characteristics
Generator loading and system impedance
Both manufacturers offer alternators that may be suitable for UPS and data center applications.
The decision should be based on actual electrical requirements rather than brand preference.
For sensitive loads, request information about voltage regulation, transient recovery, harmonic performance, alternator sizing and compatibility with the connected power electronics.
A correctly engineered generator system may also require additional consideration of UPS input characteristics, load steps and redundancy.
Alternator efficiency affects the mechanical power required from the engine and contributes to the overall efficiency of the generator set.
However, efficiency varies by model, rating, operating temperature, voltage, frequency and load percentage.
Two alternators with the same nominal kVA rating may have different efficiency curves.
For example, their losses may differ due to winding design, core materials, cooling arrangements and operating conditions.
A valid comparison should use manufacturer data measured or calculated under equivalent conditions.
Alternator insulation systems are designed for specified thermal conditions.
Many industrial alternators use insulation systems classified according to relevant international standards.
However, insulation class alone does not establish the permitted continuous output.
Engineers must also consider:
Rated temperature rise
Ambient temperature
Cooling performance
Duty classification
Installation altitude
Manufacturer derating instructions
Both Stamford and Leroy-Somer offer products for extended operating applications.
The correct selection depends on the required prime or continuous rating, expected load profile, operating temperature and maintenance arrangements.
Neither brand should automatically be considered superior for continuous operation without comparing the relevant models.
Alternators must be mechanically and electrically compatible with the diesel engine.
Both brands offer configurations that can be integrated with major industrial engine platforms.
However, compatibility should be confirmed for each engine-alternator combination.
The alternator must support the required electrical output at the intended operating speed.
Typical four-pole generator configurations operate at:
1500 rpm for 50 Hz applications
1800 rpm for 60 Hz applications
Other speeds and pole configurations are available for specialized systems.
Engine and alternator coupling arrangements must match the required mechanical interface.
Important considerations include:
SAE housing size
Flywheel interface
Coupling arrangement
Single-bearing or double-bearing construction
Shaft alignment and mounting requirements
An SAE-compatible interface alone does not guarantee complete compatibility.
The rotating engine and alternator assembly must be evaluated for torsional compatibility.
For applicable projects, the engine and generator manufacturers or qualified system integrator should review torsional vibration characteristics.
This helps reduce the risk of mechanical resonance and coupling damage.
Alternator length, weight, mounting configuration and cooling clearance can affect generator enclosure design.
A PMG-equipped alternator may require a different overall mechanical arrangement from a corresponding AREP-equipped model.
However, dimensions must be compared using actual model drawings rather than assuming that one brand always occupies less space.
DIYPOWER provides Alternators and Parts for generator applications, allowing customers to evaluate component requirements alongside complete generator set specifications.
For B2B generator buyers, the cost of ownership extends beyond the initial equipment purchase.
Maintenance support and parts availability can significantly affect downtime.
STAMFORD provides technical documentation and replacement part support through its service and distribution arrangements.
Before purchasing, buyers should confirm the availability of the specific AVR, bearings, rotating rectifier components and other maintenance parts required for their alternator model.
Leroy-Somer also provides technical support and replacement components through its service channels.
Buyers should verify the availability of model-specific AVRs, excitation components, bearings and technical documentation in their region.
Rather than assuming that one manufacturer has better global support, evaluate:
Authorized service availability in the project country
Genuine spare parts availability
Local technician capability
Expected replacement component delivery time
Warranty terms
Maintenance documentation
Repair or replacement costs
Procurement tip: Request the complete alternator model designation, serial number, technical datasheet and applicable warranty information when buying a generator set.
The following checklist can help B2B purchasers compare suitable alternators.
Selection Requirement |
What to Check |
|---|---|
Rated capacity |
Required kVA and kW |
Frequency and voltage |
50/60 Hz and system voltage |
Duty rating |
Standby, prime or continuous |
Excitation system |
Self-excited, auxiliary winding, PMG or AREP |
Motor starting |
Starting kVA and permitted voltage dip |
Nonlinear loads |
UPS, VFD and harmonic characteristics |
Environmental conditions |
Ambient temperature and altitude |
Engine compatibility |
SAE arrangement, speed and coupling |
Physical dimensions |
Space, cooling and mounting |
Maintenance |
Genuine parts and regional support |
Budget |
Complete generator set and lifecycle cost |
A particular Stamford model meets your electrical specifications, required excitation configuration, physical installation constraints and maintenance requirements.
Stamford may be a suitable option when the project requires a specific PMG-equipped configuration or when locally available support meets the customer's operating needs.
A particular Leroy-Somer model meets the required capacity, load characteristics, mechanical dimensions and service requirements.
Leroy-Somer may be a suitable option where an AREP-equipped configuration matches the project's technical requirements or the customer prefers an available TAL or LSA model.
For many customers, the alternator is selected as part of a complete diesel generator set.
A technically suitable alternator must be coordinated with the engine, controller, electrical protection, enclosure and operating conditions.
At DIYPOWER, we help customers evaluate generator set configurations for different commercial and industrial applications.
Neither brand is universally superior. Both manufacture alternators for industrial and commercial generator applications. The better choice depends on the specific model, required output, electrical load, excitation system and local maintenance support.
PMG uses a separate permanent magnet generator to supply excitation power to the AVR. AREP uses auxiliary stator windings for excitation supply. Both approaches can support demanding applications, but their performance must be evaluated using model-specific data.
Motor starting performance depends on the alternator's starting kVA capability, excitation system, AVR, load characteristics and permitted voltage dip. Both manufacturers offer configurations suitable for motor starting applications.
Both brands offer alternator configurations that can be integrated with different diesel engines. However, the specific engine-alternator pairing must be verified for rated power, speed, SAE interface, coupling and torsional compatibility.
Both manufacturers offer alternators that may be suitable for data centers. Engineers should compare transient voltage performance, nonlinear load compatibility, required rating and the complete generator system design.
Replacement components should not be assumed to be interchangeable between brands or models. Genuine or manufacturer-approved parts should be selected using the exact alternator and component specifications.
No. The excitation arrangement is only one factor. Voltage regulation also depends on the AVR, alternator design, load conditions and manufacturer specifications.
Not necessarily. Higher kVA provides additional nominal capacity, but motor starting, thermal performance, efficiency and voltage response must also be considered.
Choosing between a Stamford and Leroy Somer alternator requires more than comparing brand reputation or nominal kVA ratings.
Both offer alternator technologies suitable for commercial, industrial, standby and extended-operation generator applications.
The most important factors include excitation design, voltage regulation, motor starting capability, thermal rating, mechanical compatibility and regional service support.
For many diesel generator projects, the best approach is to compare complete engine-alternator configurations under the actual application requirements.
At DIYPOWER, we help customers evaluate diesel generator set solutions based on electrical capacity, application conditions and equipment specifications.
Explore our Generator Set Range and Alternators & Parts, or contact DIYPOWER to discuss your generator configuration and alternator requirements.